The Data Browser, activated by clicking, allows you to rename, hide, or display data in the open file. Individual datasets can be renamed by selecting Data > Data Set Options and selecting the appropriate data set from the menu.ĭata Management and Analysis: As multiple data sets are collected, they will be displayed simultaneously on the screen, which can be somewhat messy. Overwritten data is lost and cannot be recovered. Selecting Experiment > Store Latest Run places the most recently acquired data into a new column in this spreadsheet (usually named “Run #”). If you intend to save your data for later use, it is important to “store” this run before collecting a new dataset, because it will be overwritten by the new data. The table can be used to store several individual runs, the most recently collected data set is called “ Latest “. As data is collected, it is recorded in the table on the left of the screen and plotted on the graph on the right.
Vernier computer interface logger pro pro#
It is very likely that the LabPro interface and Logger Pro software will have automatically recognized the sensor you have installed on the device.Open a new file by selecting File > New from the menu bar.It will likely be worth your time to explore these (don’t forget the “Help” menu)

The button and menu bars across the top of the window contain many useful data handling and analysis functions. The right portion of the screen will present a graphical display of the data. Data can also be copied and pasted to and from Excel for plotting or manipulation. Multiple runs can be stored in a single table. The left portion of the screen is a spreadsheet-like table which will hold data that is collected. The opening screen should appear as below.

Depending on the specific measurement being done, additional connections or preparation may be necessary. Connect the appropriate sensor(s) to one of the four channel inputs on the left side if the LabPro.Verify that the LabPro interface is plugged into a USB port on the computer, and that the power supply for the LabPro is plugged in (green light is lit).More detailed instructions are available from Vernier. This document provides the basics that you will need to set up the interface, connect a sensor (or sensors) and acquire data. Once data is collected, the Logger Pro software provides several options for basic data analysis. This LabPro interface is an analog to digital converter capable of being applied to several measurement scenarios, from temperature and pH measurement, to instrument interfacing. Vernier’s Logger Pro is a software package that can be used to control a simple data acquisition system attached to a USB port of the computer. Basic Data Collection and Analysis Using Logger Pro 3